ABB ACS800-U7 Drive
The ABB ACS800-u7 Drive is tailored built for your heavy duty industrial application and offers many standard configurations that will adapt to your application needs. Each drive is contained in it’s own cabinet and can have an additional cabinet added for your specific devices and application needs.
The ACS800-U7 has a wide range of built in features and option including extended I/O and fildbus options, EMC filtering and common mode filtering.
ABB ACS800-U7 Drive Features
- Power ratings from 75 – 600 Hp
- Built in harmonic filtering AC choke
- Common mode filters for motor protection
- Programmable I/O
ACS800-U7 Options
Built In
- Analog and digital I/O extension modules
- Brake chopper and resistor
- Cabinet heater
- Customer terminal block
- Ground fault monitoring for ungrounded network
- EMC filter for 1st environment, restricted distribution according to EN 61800-3
- EMC filter for 2nd environment, restricted distribution according to EN 61800-3
- Fieldbus modules
- UL Type 1 Filtered and UL Thye 1 enclosure classes
- Line contactor with emergency stop push button
- Output for auxiliary fan motor
- Pulse encoder interface module
- Prevention of unexpected motor start up
- 1 or 2 thermistor relays
- 3, 5 or 8 PT100 relays
- Resolver Interface (Limited software support)
Why a IFS ABB Professional?
- Your own ABB drive professional consultant from start to finish
- Professional ABB drive configuration
- Certified ABB drive startups
- Rush Orders
ABB ACS800-U7 Ratings and Dimensions
Supply Voltages 380-500
Type Designation | Frame Size |
Input A |
Imax A |
I2N A |
PN Hp |
I2HD A |
PHD Hp |
Noise Level dBA |
Air Flow ft3/min |
Head Dissipation BTU/hr |
---|---|---|---|---|---|---|---|---|---|---|
ACS800-U7-0100-5 | R6 | 121 | 164 | 124 | 100 | 96 | 75 | 63 | 238 | 6610 |
ACS800-U7-0120-5 | R6 | 155 | 202 | 157 | 125 | 124 | 100 | 63 | 238 | 7890 |
ACS800-U7-0140-5 | R6 | 180 | 282 | 180 | 150 | 156 | 125 | 63 | 238 | 9600 |
ACS800-U7-0170-5 | r7 | 191 | 326 | 192 | 150 | 162 | 125 | 71 | 318 | 10100 |
ACS800-U7-0210-5 | R7 | 243 | 384 | 240 | 200 | 192 | 150 | 71 | 318 | 12900 |
ACS800-U7-0260-5 | R7 | 291 | 432 | 286 | 200 | 224 | 150 | 71 | 718 | 15300 |
ACS800-U7-0270-5 | R8 | 299 | 480 | 316 | 250 | 240 | 200 | 72 | 718 | 15350 |
ACS800-U7-0300-5 | R8 | 336 | 568 | 361 | 300 | 302 | 250 | 72 | 718 | 18050 |
ACS800-U7-0320-5 | R8 | 424 | 588 | 435 | 350 | 340 | 250 | 72 | 708 | 23250 |
ACS800-U7-0400-5 | R8 | 498 | 588 | 510 | 400 | 370 | 300 | 72 | 718 | 26650 |
ACS800-U7-0440-5 | R8 | 543 | 840 | 545 | 450 | 490 | 400 | 72 | 718 | 25950 |
ACS800-U7-0490-5 | R8 | 590 | 840 | 590 | 500 | 515(1) | 450 | 72 | 718 | 27600 |
ACS800-U7-0550-5 | R8 | 669 | 1017 | 670 | 550 | 590(1) | 500 | 72 | 718 | 31100 |
ACS800-U7-0610-5 | R8 | 702 | 1017 | 704 | 600 | 590(1) | 500 | 72 | 728 | 33000 |
Suppy Voltages 525-60
Type Designation | Frame Size |
Input A |
Imax A |
I2N A |
PN Hp |
I2HD A |
PHD Hp |
Noise Level dBA |
Air Flow ft3/min |
Head Dissipation BTU/hr |
---|---|---|---|---|---|---|---|---|---|---|
ACS800-U7-0070-7 | R6 | 95 | 104 | 73 | 60 | 54 | 50 | 65 | 235 | 4200 |
ACS800-U7-0100-7 | R6 | 121 | 124 | 86 | 75 | 62 | 60 | 65 | 238 | 5650 |
ACS800-U7-0120-7 | R6 | 155 | 172 | 108 | 100 | 86 | 75 | 65 | 238 | 6700 |
ACS800-U7-0140-7 | R7 | 126 | 190 | 125 | 125 | 95 | 100 | 71 | 318 | 9600 |
ACS800-U7-0170-7 | R7 | 156 | 263 | 155 | 150 | 131 | 125 | 71 | 318 | 12150 |
ACS800-U7-0210-7 | R7 | 191 | 294 | 165/195(2) | 150/200(2) | 147 | 150 | 71 | 318 | 14550 |
ACS800-U7-0260-7 | R7 | 217 | 326 | 175/212(2) | 150/200(2) | 163 | 150 | 71 | 318 | 16400 |
ACS800-U7-0320-7 | R8 | 298 | 433 | 290 | 300 | 216 | 200 | 72 | 718 | 21050 |
ACS800-U7-0400-7 | R8 | 333 | 548 | 344 | 350 | 274 | 250 | 72 | 718 | 22750 |
ACS800-U7-0440-7 | R8 | 377 | 656 | 387 | 400 | 328 | 350 | 72 | 718 | 25300 |
ACS800-U7-0490-7 | R8 | 423 | 775 | 426 | 450 | 384 | 400 | 72 | 718 | 28900 |
ACS800-U7-0550-7 | R8 | 468 | 853 | 482 | 500 | 426 | 450 | 72 | 718 | 28350 |
ACS800-U7-0610-7 | R8 | 533 | 964 | 537 | 500 | 482 | 500 | 72 | 718 | 33300 |
Get My ACS800 Quote
Notes
(1)50% overload is allowed if ambient temperature is 30ºC or less, overload is limited to 40% at 40ºC
(2)The higher rating is available when ouput fequency is above 41Hz.
Imax current available for 10 seconds at start.
I2N continuous base current at 40º C (104º F).
Overload cycle 110% I2N for 1 minute / 5 minutes allowed.
I2HD continuous base current at 40º C (104º F).
Overload cycle 150% I2HD for 1 minute / 5 minutes allowed.
Current ratings do not change with different supply voltages.
Horsepower ratings are based on NEMA motor ratings for typical 4-pole motors (1800 rpm). Check motor nameplate current for compatibility.