ABB ACS800-07 Drive
You’ll find a wide range of configurations that will adapt to your drive application needs and can be completely assembled and delivered to you in one package.
Each ABB ACS800-07 drive has a wide range of built in features and options including extended I/O and fieldbus options, EMC filtering, common mode filtering and more.
ABB ACS800-07 Features
- Power range 45-2800 Kw
- Direct torque control (DTC) as standard
- 12 pulse types for higher power
- Supports a wide range of fieldbus protocols
- Flexible I/O and encoder options (option)
- EMC filter, choke and brake chopper as option (option)
- UL or CSA certified design (option)
- Marine construction (option)
- Safe torque off (STO) and STEX approved motor protection (option)
ACS800-07 Drive Options
- Analog and digital I/O extension modules
- Brake chopper and resistor
- Cabinet heater
- Customer terminal block
- Bround fault monitoring for ungrounded network
- EMC filter for 1st environment, restricted distribution according to EN 62800-3
- EMC filter for 2nd environment, unrestricted distribution according to EN 61800-3
- Fieldbus modules
- UL Type 1 Filtered and UL Type 12 enclosure classes
- Line contactor with emergency stop push button
- Output for auxiliary fan motor
- Pulse encoder interface module
- Prevention of unexpected start up of motor
- 1 0r 2 themistor relays
- 3, 5, or 8 PT100 relays
- Resolver Interface (Limited software support)
Other options may be tailor added through the ABB application engineering team.
Why a IFS ABB Professional?
- Your own ABB drive professional consultant from start to finish
- Professional ABB drive configuration
- Certified ABB drive startups
- Rush Orders
ABB ACS800-07 Ratings and Dimensions
Supply Voltages 380-500
Type Designation | Frame Size |
Input A |
Imax A |
I2N A |
PN Hp |
I2HD A |
PHD Hp |
Noise Level dBA |
Air Flow ft3/min |
Head Dissipation BTU/hr |
---|---|---|---|---|---|---|---|---|---|---|
ACS800-07-0760-5+C129+H359 | ID4+2R8i | 793 | 1321 | 848 | 700 | 660 | 550 | 73 | 1836 | 47800 |
ACS800-07-0910-5+C129+H359 | 2D4+2R8i | 944 | 1524 | 1008 | 900 | 785 | 700 | 74 | 2260 | 58700 |
ACS800-07-1090-5+C129+H359 | 2D4+2R8i | 1131 | 1882 | 1208 | 1000 | 941 | 800 | 74 | 2260 | 67900 |
ACS800-07-1210-5+C129+H359 | 2D4+2R8i | 1233 | 1991 | 1317 | 1150 | 1026 | 900 | 74 | 2260 | 81200 |
ACS800-07-1540- 5+A004+C129+H359 |
2D4+3R8i | 1596 | 2655 | 1704 | 1500 | 1328 | 1150 | 75 | 2966 | 100300 |
ACS800-07-1820- 5+A004+C129+H359 |
2D4+3R8i | 1831 | 2956 | 1956 | 1750 | 1524 | 1250 | 76 | 3390 | 119400 |
ACS800-07-2310- 5+A004+C129+H359 |
3D4+4R8i | 2400 | 3901 | 2563 | 2250 | 1997 | 1750 | 76 | 4096 | 154900 |
Supply Voltages 525-690
Type Designation | Frame Size |
Input A |
Imax A |
I2N A |
PN Hp |
I2HD A |
PHD Hp |
Noise Level dBA |
Air Flow ft3/min |
Head Dissipation BTU/hr |
---|---|---|---|---|---|---|---|---|---|---|
ACS800-07-0750-7+C129+H359 | 1D4+2R8i | v565 | 939 | 603 | 600 | 470 | 500 | 73 | 1836 | 47400 |
ACS800-07-0870-7+C129+H359 | 1D4+2R8i | 655 | 1091 | 700 | 750 | 545 | 600 | 73 | 1836 | 58300 |
ACS800-07-1060-7+C129+H359 | 1D4+2R8i | 795 | 1324 | 850 | 900 | 662 | 700 | 73 | 1836 | 62800 |
ACS800-07-1160-7+C129+H359 | 2D4+2R8i | 856 | 1426 | 915 | 1000 | 713 | 800 | 74 | 2260 | 7100 |
ACS800-07-1500-7+C129+H359 | 2D4+3R8i | 1131 | 1882 | 1208 | 1250 | 941 | 1000 | 75 | 2966 | 92100 |
ACS800-07-1740-7+C129+H359 | 2D4+3R8i | 1271 | 2115 | 1357 | 1500 | 1058 | 1150 | 75 | 2966 | 110900 |
ACS800-07-2120-7+C129+H359 | 2D4+4R8i | 1595 | 2654 | 1703 | 1850 | 1327 | 1400 | 76 | 3672 | 136800 |
ACS800-07-2320- 7+A004+C129+H359 |
3D4+4R8i | 1678 | 2792 | 1791 | 2000 | 1396 | 1500 | 76 | 4096 | 147700 |
ACS800-07-2900- 7+A004+C129+H359 |
3D4+5R8i | 2086 | 3472 | 2228 | 2400 | 1736 | 1900 | 77 | 4803 | 175700 |
ACS800-07-3190- 7+A004+C129+H359 |
3D4+6R8i | 2396 | 3987 | 2558 | 2800 | 1993 | 2250 | 78 | 5509 | 197900 |
ACS800-07-3490- 7+A004+C129+H359 |
4D4+6R8i | 2490 | 4144 | 2659 | 3000 | 2072 | 2300 | 78 | 5933 | 217000 |
Notes
Imax current available for 10 seconds at start.
I2N continuous base current at 40º C (104º F).
Overload cycle 110% I2N for 1 minute / 5 minutes allowed.
I2HD continuous base current at 40º C (104º F).
Overload cycle 150% I2HD for 1 minute / 5 minutes allowed.
Current ratings do not change with different supply voltages.
The rated current of the ACS800 must be greater than or equal to the rated motor current to achieve the rated motor power given in the table.
Horsepower ratings are based on NEMA motor ratings for typical 4-pole motors (1800 rpm). Check motor nameplate current for compatibility.